Is the airway volume being correctly analyzed
Ten scans from the airway prototype were obtained by using cone-beam computed tomography. The volume from each scan was measured with 8 values (25, 50, 70, 71, 72, 73, 74, and 75) of the threshold tool from the Dolphin software (Dolphin Imaging and Management Solutions, Chatsworth, Calif). The gold standard method used was the actual volume of the airway prototype, which was compared with the different threshold values. An intraclass correlation coefficient test was applied to evaluate the intraexaminer calibration and verify differences among the airway volumes measured in all cone-beam computed tomography scans. Analysis of variance with the Tukey post-hoc test was used to compare differences among the measurements with different threshold values with the gold standard.